For a comprehensive understanding of climate in a greenhouse with fan and pad system, an experiment measuring climate parameters was conducted on with two ventilation rates and with pad on and off. The transpiration rate of the plant inside greenhouse was supposed to be one of the most important factors on climate considerably influences latent heat exchange, and it was calculated and measured mainly in this work. The experimental data show that the transpiration rate has some correlation with ventilation and pad working condition. In the case of no pad working, the higher ventilation which promotes transpiration will induce a lower temperature inside greenhouse to outside and a lower leaf temperature than its ambient temperature. But with the pad working the leaf phenomena is just opposite. The vertical and horizontal distribution of temperature and specific humidity were also measured and analyzed.
參考文獻
相似文獻
引證文獻
引用本文
趙云,沈劍英,Meir Teitel.濕簾風機系統(tǒng)溫室夏季蒸騰與微氣候試驗[J].農(nóng)業(yè)機械學報,2008,39(8):109-113.[J]. Transactions of the Chinese Society for Agricultural Machinery,2008,39(8):109-113.