雙向豎井貫流泵進出水流道優(yōu)化研究
CSTR:
作者:
作者單位:

作者簡介:

通訊作者:

中圖分類號:

基金項目:

國家自然科學(xué)基金資助項目(51376155),、揚州市科技創(chuàng)新與成果轉(zhuǎn)化專項引導(dǎo)資金資助項目(YZ2011144),、揚州市揚州大學(xué)研究生科研創(chuàng)新省立校助項目(KYLX_1346)和江蘇省自然科學(xué)基金資助項目(BK20150457)


Optimization Research on Passage of Bidirectional Shaft Tubular Pump Shaft Tubular Pump
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 圖/表
  • |
  • 訪問統(tǒng)計
  • |
  • 參考文獻
  • |
  • 相似文獻
  • |
  • 引證文獻
  • |
  • 資源附件
  • |
  • 文章評論
    摘要:

    基于RNG k-ε紊流模型和雷諾時均N-S方程,運用商用CFD軟件對雙向豎井貫流泵裝置進行了三維流動數(shù)值仿真計算,。對流道內(nèi)的水力損失分析借鑒了微元法分析原理,通過對比分析分段水力損失可知:豎井作為進水流道時,,其尾部匯合處水力損失較大,,直管式出水流道在靠近導(dǎo)葉出口端水力損失較大,豎井作為出水流道在分叉處水力損失較大,。通過調(diào)整豎井及直管式流道型線,,有效減小水力損失,泵裝置外特性有了較好的提升,,最終完成水力性能優(yōu)化設(shè)計,。最終優(yōu)化后的雙向豎井貫流泵裝置在葉片安放角為0°時數(shù)值計算結(jié)果正向運行效率最高達72.0%,反向為57.9%,;模型試驗結(jié)果正向運行效率最高達70.4%,,反向為56.2%。

    Abstract:

    Based on the RNG k-ε turbulent model and Reynolds Navier-Stokes equation, the hydraulic performance of the bidirectional shaft tubular pump was simulated with the commercial CFD software. By comparing the hydraulic loss of each part, the results indicated that the hydraulic loss at the tail of the shaft tubular was large when the shaft tubular was used as inlet passage, and the hydraulic loss near the outlet of the vane and the bifurcation of the shaft tubular was also large when the shaft tubular was used as outlet passage. The hydraulic losses of the shaft tubular and straight passage were small when they were used as inlet passages due to the frictional head loss, but the hydraulic losses were large when they were used as outlet passages, with the effect of circulation and spread section, the flow was easy to be taken off, thus the hydraulic losses were large. The performance of the pump unit was improved compared with the original case, as the head loss was significantly reduced by adjusting the hull lines of the flow channel, and finally the hydraulic performance optimization design was finished. The efficiency of the simulation was up to 72.0% under positive condition, and it was up to 57.9% under reverse condition, the efficiency of the model test was up to 70.4% under positive condition, and it was up to 56.2% under reverse condition.

    參考文獻
    相似文獻
    引證文獻
引用本文

謝榮盛,吳忠,何勇,湯方平,謝傳流,涂戀戀.雙向豎井貫流泵進出水流道優(yōu)化研究[J].農(nóng)業(yè)機械學(xué)報,2015,46(10):68-74. Xie Rongsheng, Wu Zhong, He Yong, Tang Fangping, Xie Chuanliu, Tu Lianlian. Optimization Research on Passage of Bidirectional Shaft Tubular Pump Shaft Tubular Pump[J]. Transactions of the Chinese Society for Agricultural Machinery,2015,46(10):68-74.

復(fù)制
分享
文章指標
  • 點擊次數(shù):
  • 下載次數(shù):
  • HTML閱讀次數(shù):
  • 引用次數(shù):
歷史
  • 收稿日期:2014-12-18
  • 最后修改日期:
  • 錄用日期:
  • 在線發(fā)布日期: 2015-10-10
  • 出版日期: 2015-10-10
文章二維碼