ass日本风韵熟妇pics男人扒开女人屁屁桶到爽|扒开胸露出奶头亲吻视频|邻居少妇的诱惑|人人妻在线播放|日日摸夜夜摸狠狠摸婷婷|制服 丝袜 人妻|激情熟妇中文字幕|看黄色欧美特一级|日本av人妻系列|高潮对白av,丰满岳妇乱熟妇之荡,日本丰满熟妇乱又伦,日韩欧美一区二区三区在线

拖拉機防護裝置自動靜載試驗系統(tǒng)設計
CSTR:
作者:
作者單位:

作者簡介:

通訊作者:

中圖分類號:

基金項目:

江蘇省農機三新工程項目(NJ2017-08)


Design of Automatic Static Load Test System of Tractor Roll-over Protective Structures
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 圖/表
  • |
  • 訪問統(tǒng)計
  • |
  • 參考文獻
  • |
  • 相似文獻
  • |
  • 引證文獻
  • |
  • 資源附件
  • |
  • 文章評論
    摘要:

    針對拖拉機防護裝置靜態(tài)試驗設備調節(jié)繁瑣、自動化程度和作業(yè)效率低等問題,,設計了拖拉機防護裝置自動靜載試驗系統(tǒng),。該試驗系統(tǒng)由機械加載及輔助系統(tǒng)、液壓系統(tǒng)和測控系統(tǒng)等組成,,采用一次性夾持固定拖拉機防護裝置,,通過三維移動加載立柱、壓垮橫梁以及手動/遙控調節(jié),、自動加載等方式,,實現拖拉機防護裝置在不同工況下的靜載試驗,。利用該試驗系統(tǒng)對WD1104型輪式拖拉機駕駛室進行了水平縱向加載、側向加載和2次垂直壓垮試驗,,試驗結果表明,,系統(tǒng)性能穩(wěn)定,縱向加載和側向加載下的能量控制誤差分別為0.55%,、0.03%,,垂直后壓垮和垂直前壓垮試驗壓垮力控制誤差分別為0.63%、0.16%,,滿足相關標準對試驗設備的要求,。

    Abstract:

    Aiming to solve the problem of the cumbersome adjustment of the static test equipment of tractor roll-over protective structures, high labor intensity, the low degree of automation and efficiency of operation, a static load test system for tractor roll-over protective structures which can greatly reduce labor force, improve automation level and increase the utilization of site was developed. Based on the modular design of the test system, it was composed of mechanical loading and auxiliary system, hydraulic power source system, data acquisition and processing system, control system, etc. The tractor roll-over protective structure was fixed by disposable clamping, and the static load test of the tractor roll-over protective structures under different working conditions was realized by moving the loading column in different spatial locations, pressing the beam, manual or remote adjustment and automatic loading and so on. The test system established the communication between the industrial computer and the PLC, it had a wide range of applications, and it can not only test the four-post and six-post cabs of agricultural machinery, but also test the folding and nonfolding safety frames. The horizontal longitudinal, lateral and two times vertical pressure tests of WD1104 wheeled tractor safety cab were carried out by using the test system. The results showed that the performance of the system was stable, the energy control error under longitudinal loading and lateral loading was 0.55% and 0.03%, the crushing force control error of vertical rear crushing and vertical front crushing tests was 0.63% and 0.16%, respectively. Therefore, the static load test system can meet the requirements of the relevant standards for test equipment.

    參考文獻
    相似文獻
    引證文獻
引用本文

劉德營,李和清,卞兆娟,閆一哲,張華希,於海明.拖拉機防護裝置自動靜載試驗系統(tǒng)設計[J].農業(yè)機械學報,2020,51(7):406-412. LIU Deying, LI Heqing, BIAN Zhaojuan, YAN Yizhe, ZHANG Huaxi, YU Haiming. Design of Automatic Static Load Test System of Tractor Roll-over Protective Structures[J]. Transactions of the Chinese Society for Agricultural Machinery,2020,51(7):406-412.

復制
分享
文章指標
  • 點擊次數:
  • 下載次數:
  • HTML閱讀次數:
  • 引用次數:
歷史
  • 收稿日期:2019-11-11
  • 最后修改日期:
  • 錄用日期:
  • 在線發(fā)布日期: 2020-07-10
  • 出版日期:
文章二維碼